VI TELEFILTER Filter specification TFS 299

by user

on
Category: Documents
3

views

Report

Comments

Transcript

VI TELEFILTER Filter specification TFS 299
Filename: tfs 299.doc
Version 1.9
VI TELEFILTER
13.10.2006
Filter specification
TFS 299
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0±2
°C
dBm
625 Ω || -5,3 pF
520 Ω || -5,1 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 299 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 299 is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
6,2
Nominal frequency
fN
-
tolerance / limit
dB
max.
8,0
299,0
fN
± 80
dB
MHz
kHz
Passband
PB
-
Pass band ripple
p-p
0,3
dB
max.
Bandwidth
3 dB
BW
1,1
MHz
min.
400
kHz
Relative attenuation
arel
dB
dB
dB
dB
min.
min.
min.
min.
20
35
20
20
dB
dB
dB
dB
µs
max.
1
µs
ns
max.
1
µs
-
max.
+10
-
-40 °C ... + 85 °C
fN
fN
fN
fN
±
±
+
1,8
6,0
298,0
60,0
MHz
MHz
MHz
MHz
...
...
...
...
fN
fN
fN
fN
±
±
+
6,0
60,0
60,0
701,0
MHz
MHz
MHz
MHz
Absolute group delay at fN
Group delay ripple within PB
0,77
p-p
Input power level
Operating temperature range
OTR
Storage temperature range
95
-
Frequency inversion temperature
Temperature coefficient of frequency
23
40
45
46
TCf **
±0,5
dB
dBm
-40 °C ... + 90 °C
25
°C
-0,036
ppm/K
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 299.doc
Version 1.9
VI TELEFILTER
13.10.2006
Filter specification
TFS 299
2/5
0
0
-10
-1
-20
-2
-30
-3
-40
-4
magnitude in dB
magnitude in dB
Filter characteristic
-50
-60
-5
-6
-70
-7
-80
-8
-90
-9
-100
294.4
295.3
296.2
297.1
298
298.9
299.8
frequency in MHz
300.7
301.6
302.5
-10
298.4
303.4
298.5
298.6
298.7
298.8
298.9
299
frequency in MHz
299.1
299.2
299.3
299.4
Construction and pin connection
(All dimensions in mm)
TFS 299
●
U41
1
3
2 Max.
7,3 Max.
9,3 Max.
Date code
1
2
3
4
5
6
7
8
9
10
Output
Ground
Ground
Ground
Ground
Input
Ground
Ground
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
2,54
5,08
0,8
R0
,3
0,1
0,9
50 Ω Test circuit
L1
6
1
L2
SAW
C2
C1
2, 3, 4, 5, 7, 8, 9, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 299.doc
Version 1.9
VI TELEFILTER
13.10.2006
Filter specification
TFS 299
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
5. ESD
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
MIL-STD-883E using coupling network of ISO 10605 and EN 6100-4-2
HBM:250V; MM:200V; CDM:V;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
2000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
P1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 299.doc
Version 1.9
VI TELEFILTER
13.10.2006
Filter specification
TFS 299
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 299.doc
VI TELEFILTER
Version 1.9
Filter specification
13.10.2006
TFS 299
5/5
History
Version
Reason of Changes
Name
Date
1.6
- impedances modified
- date code changed and explained
- tape and reel dimensions corrected
Steiner
24.03.2000
Steiner
12.07.2000
1.8.
- ESD limits added
- Storage temperatur range added
- Change remark
Strehl
17.09.2004
1.9
- Add typ. value and filter characteristic
Strehl
13.10.2006
1.7
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Fly UP